Boiler Specifications

 
Specifications:
YANKEE Boiler
ADD-ON Boiler
UNIT SIZE YCB 24
YCOB 24
YWB 24
YWOB 24

YCB 36
YCOB 36
YWB 36
YWOB36

AOB24W
AOB24C
AOB36W
AOB36C
HEAT EXCHANGER




BTU/H Wood 70,000 100,000
70,000 100,000
BTU/H Coal 100,000 175,000
100,000 175,000
Grate Surface (sq. ft.) 2.95 4.43
2.95 4.43
Net Coal Capacity (lbs.) 150 220
150 220
Net Wood Capacity (lbs.) 95 145
95 140
Firing Rate, GPH #2 Oil .65 .65


BTU Oil 73,000 73,000


Wood Length 24" 36"
24" 36"
WATER INFORMATION




Capacity (Gal.) 25 35
25 35
Supply Tapping (1) 1 1/2" 1 1/2"
1 1/2" 1 1/2"
Return Tapping (1) 1 1/2" 1 1/2"
1 1/2" 1 1/2"
Tankless Coil Capacity (gal.) 3 3


Tankless Coil Tapping (2) 1/2" 1/2"


CABINET DIMENSIONS




Width 22 1/4" 22 1/4"
22 1/4" 22 1/4"
Length 30 1/2" 42 1/2"
30 1/2" 42 1/2"
Height 45 3/4" 45 3/4"
45 3/4" 45 3/4"
Firing Door Size (h x w) 11" x 15" 11" x 15"
11" x 15" 11" x 15"
Stack Diameter 7" 7"
7" 7"
Stack center from floor 35" 35"
35" 35"
Shipping Weight (lbs.) 725 930
625 725

 

Duvall Heating & Air Conditioning Inc.  

500 Third Avenue  Elizabeth Pennsylvania 15037 (USA)

Tel- (412)384-6972 Toll Free Fax- (877)349-3005

Duvall@DuvallHeatCool.com

Hit Counter

02/10/2006